PRODUCT SUPPORT, RETURNS AND RMA PROCEDURES, HELP
|
|
PRODUCT RETURNS and REPAIR PROCEDURE |
| USA and International: |
Canada: |
Any product being returned for
repair must have an RMA (Returned Merchandise Authorization) number.
To obtain an RMA, please call our Manufacturing facility at the number
listed below.
Product must be shipped prepaid and include your contact information and
return address. Ship to the address below. |
For product being returned from
Canada only, ship prepaid and include contact information and return
address to
our head office at the address below. |
| |
JB Systems Inc.
4944 - 113th Avenue N
Clearwater, FL. 33760Tel: (727) 545-3900 |
|
IRIS Systems Inc.
7583 Vantage Place
Delta, BC.,
V4G 1A5Tel: (604) 584-4747 |
| An estimate will be provided for all repairs
that are out of warranty. A $75.00 minimum charge will apply. |
|
MANUALS, BROCHURES AND DOCUMENTATION |
| CLICK
HERE TO GO TO THE DOWNLOAD PAGE |
|
FREQUENTLY ASKED QUESTIONS (FAQ) |
| This section is under ongoing development |
|
|
|
FAQ |
|
S550B, S552B and S556B Viewing Heads |
Q. No Signal from the
viewing head when used with Models P520 or P522 Signal processors.
-
The viewing head was disconnected from the
Signal processor while powered up. Reconnect the cable and cycle
the power
-
The Source Impedance resistors that came wired
to the viewing head connector on the P522 were removed, or were
not installed on the P520. Re-install the resistor.
NOTE: A source impedance resistor is required when using the
P522/P520 signal Processor with a S550B, S552B or S556B viewing
head. The resistor should be 330 ohms 1/4 watt (factory installed
on the viewing head connector on the P522, or included in the box
with the P520 Signal Processor) for viewing head cable lengths up
to 500 feet.
For Cable lengths of 500 to 1000 feet, the resistor value should
be 150 ohms 1/4 watt. This resistor is included in the box with
either processor. The resistor should be connected across the SC
and SIG GND terminals on the signal processor.
-
The Red plug on the viewing head is wired
incorrectly.
When using the C328 cable, ensure that the white wire is
connected to the SIG terminal of the signal processor connector
and the shield that surrounds the white signal wire is wired to
SIG GND.
|
|
Return to top |
|
M700, 800 Signal Processors and 700 / 800 Viewing
Heads |
Q. There is a no signal indication
|
|
 |
|
Q. Communication stopped on RS422
Q. How do I attach conduit to Models
700/800 viewing heads using c330 cable
Q. What is the procedure for doing analog output
calculations for the 700 Signal Processor?
Convert (0 to 20) to (4 to 20):
|
|
Return to top |
|
FlameTools
for Palm OS |
Q. Will my Palm run FlameTools for
Palm?
Flame Tools for Palm OS has been tested on the following
devices:
Devices not supported
These are a few devices without EIA 232 (rs232) support and will
not work.
-
Zire 21
-
Zire 31
-
Zire 72
-
Tungsten E
Future devices:
Palm has not yet designed an EIA 232 cable for the newest products.
We have been in contact with the designers and will be notified when
a cable becomes available.
-
Treo 650 (no Cable)
-
Tungsten 5 (no Cable)
IRIS offers an easy connection solution for interfacing supported
Palm to IRIS processors:
|
| Return to top |
|
P531, P532, P520,
P522 Signal Processors |
Q. What is the procedure for analog
output calculations?
Q. Do IRIS Signal Processors support 2 wire RS-485?
Q. Why does channel "B" not see the S55x Viewing Head?
-
Configuration requires detection of the S55x Viewing Head once
for each channel and detection can only happen at power up.
Once detected, the model number of the Viewing head is saved
internally and will not need detection again unless the model
number of the Viewing Head is changed.
This enables compatibility with Viewing Heads that have no gain
adjustments which do not require detection.
Procedure:
1) Select channel "B" by applying power to the "Chan Sel" pins
2) Cycle power to the processor.
|
| Return to top |
|
|
|